WICHTIGSTE PUNKTE
Online-Überwachung jedes Instruments
Zugang und Support zum Online-Service
Europäisches Produkt
Begrenzter Platzbedarf
Geschlossenes System mit der Möglichkeit offener Kanäle
Austausch von Verbrauchsmaterialien – schnell und einfach
Timer und Fernstart von Santhia 240 Premium
FILM
PARAMETER
- ALBUMIN
- ALP
- ALT
- AMYLASE
- AMYLASE
- AST
- BILIRUBIN DIRECT
- BILIRUBIN TOTAL
- CALCIUM
- CHLORIDE
- CHOLESTEROL
- CHOLINESTERASE
- CK-MB
- CK-MB
- CK-NAC
- CK-NAC
- CREATININE ENZ
- CREATININE JAFFE
- y-GT
- GLUCOSE
- HDL DIRECT
- IRON
- LDH
- LDL DIRECT
- LIPASE
- MAGNESIUM
- PHOSPHORUS
- TOTAL PROTEIN
- TRIGLYCERIDES
- UREA
- URIC ACID
- URINARY & CSF PROTEINS
- a-1-ANTITRIPSIN
- a-1-GLYCOPROTEIN ACID
- ANTITHROMBIN III
- APOLIPOPROTEIN A-I
- APOLIPOPROTEIN B
- ASO
- b-2-MICROGLOBULIN
- C3
- C4
- CERULOPLASMIN
- CRP
- FERRITIN
- HAPTOGLOBIN
- HbA1c
- IgA
- IgG
- IgM
- Lp(a)
- mALB
- PREALBUMIN
- RF
- TRANSFERRIN
- IgE
- ADA
TECHNISCHE SPEZIFIKATION
Analysis |
System type |
Random/Urgent (sample attribute) |
Throughput |
Up to 220 tests/h (fixed cycle) |
|
Analysis method |
Endpoint, Bichromatic endpoint, Differential endpoint, Differential |
|
Calibration |
Up to 8 points per test method (linear, spline, logit-log, etc.) |
|
Sample |
Sample tray |
Removable tray, 32 positions |
Sample container |
Tubes 12-13 mm x 75 mm or cups on adapter (1mL) |
|
Sample volume |
2-300 μL |
|
Dilution |
In-needle dilution if allowed by method’s sample volumes |
|
Sample barcode |
Internal barcode reader | |
Reagent |
Bottle volume |
40 mL, 25 mL, 15 mL, 2 mL |
Reagent volume |
5-350 μL |
|
Reagent storage |
Reagent tray cooling 13oC below room temperature |
|
Reagent tray |
Removable rack, 32+32 bottles | |
Reagent barcode |
Internal barcode reader | |
Pipetting system |
Sampling arm |
1 sampling needle washed internally and externally |
Capacitive liquid level detector | ||
Reaction | Cuvette | 80 washable BIONEX® cuvettes |
Reaction volume |
190-350 μL |
|
Reaction time |
Maximum incubation + reading time: 800 seconds |
|
Reaction temperature |
37oC (heating unit can be set from room temperature up to 42oC |
|
Optical measurement |
8 fixed wavelengths (340-700 nm), 1 free position, 1 for dark reading |
|
Optical source |
1 halogen lamp (6V, 10W) with extended UV emission |
|
Optical path |
6 mm | |
Cuvette washing |
8 step washing sequence for each cuvette |
|
User interface | Communication |
USB port |
Printing reports |
Single test, complete sample, work sheet, method and QC |
|
Power supply |
100-240 V, 50/60 Hrz |
|
Dimension |
54 x 60 x 64 cm (W x D x H) |
|
Weight |
40 kg |
UNTERNEHMENSINFORMATIONEN
TERSACO AG
Calendariaweg 2
6405 Immensee (SZ)
Küssnacht, Switzerland
TEL | +41 41 729 36 39 |
office@tersaco.ch | |
HR NO. | CH-170.3.040.690-5 |
UID | CH-467.438.113 |
ISO 13485:2016
ID 9108642026
All rights reserved.